Measuring head for blind bores, accuracy better than 0.002 mm
Product description
The head connects to a holder and a suitable dial or digital indicator, or a probe with a digital readout. Set the assembly against a suitable reference such as a setting ring.
Each head is ordered for a specific bore diameter and tolerance. The stated intervals identify nominal-diameter groups, not the adjustable range of a single head. Please specify the nominal diameter, upper and lower deviations, and required measuring depth when ordering.
Key features
- Two-contact comparative measurement
- Self-centering measuring head
- M11 × 0.75 connection thread
Holders PH12-160, PH12-235, PH18-160, PH18-235 and PH12-40 are suitable for analog or digital indicators. Holder PH-DS is intended for probes with an 8 mm mounting diameter.
To verify a particular head and holder combination, contact the sales department of JIRKA a spol.
| Order number | Diameter group (mm) | Contact travel (mm) | Accuracy (mm) | Technical drawing |
|---|---|---|---|---|
| PGD-B60200 | 60.0–200 | 0.3-0.4 | < 0.002 | ![]() |
The photograph is illustrative.